export interface PhaseD3FindingCategorySeed { code: string; name: string; sortOrder: number; } export interface PhaseD3FindingCatalogItemSeed { code: string; categoryCode: string; sourceNumber: number; title: string; legalBasis: string | null; glossary: string | null; importNote: string | null; } export const PHASE_D3_FINDING_CATEGORIES: PhaseD3FindingCategorySeed[] = [ { "code": "TANQUES", "name": "Tanques", "sortOrder": 1 }, { "code": "SEPARADORES", "name": "Separadores", "sortOrder": 2 }, { "code": "BOMBAS", "name": "Bombas y zona de bombas", "sortOrder": 3 }, { "code": "CALDERAS", "name": "Calderas", "sortOrder": 4 }, { "code": "DRENAJE", "name": "Drenaje", "sortOrder": 5 }, { "code": "ANTORCHA", "name": "Antorcha", "sortOrder": 6 }, { "code": "COLECTORES", "name": "Colectores", "sortOrder": 7 }, { "code": "SISTEMA_ELECTRICO_ILUMINACION", "name": "Sistema eléctrico e iluminación", "sortOrder": 8 }, { "code": "DEFENSA_CONTRA_INCENDIOS", "name": "Defensa contra incendios", "sortOrder": 9 }, { "code": "CARGADERO_DESCARGADERO", "name": "Cargadero y descargadero de camiones", "sortOrder": 10 }, { "code": "FILTROS", "name": "Filtros", "sortOrder": 11 }, { "code": "EQUIPO_FLOTACION", "name": "Equipo de flotación", "sortOrder": 12 }, { "code": "BATERIAS_PLANTAS", "name": "Baterías y plantas", "sortOrder": 13 }, { "code": "FWKO_TRATADORES_CALENTADORES", "name": "FWKO, tratadores y calentadores", "sortOrder": 14 }, { "code": "BOMBEO_MECANICO", "name": "Bombeo mecánico", "sortOrder": 15 }, { "code": "BOMBEO_ELECTROSUMERGIBLE", "name": "Bombeo electrosumergible", "sortOrder": 16 }, { "code": "BOMBEO_CAVIDAD_PROGRESIVA", "name": "Bombeo de cavidad progresiva (PCP)", "sortOrder": 17 }, { "code": "POZOS_SURGENTES_GAS", "name": "Pozos surgentes y productores de gas", "sortOrder": 18 }, { "code": "POZOS_INYECTORES_AGUA", "name": "Pozos inyectores de agua", "sortOrder": 19 } ]; export const PHASE_D3_FINDING_CATALOG_ITEMS: PhaseD3FindingCatalogItemSeed[] = [ { "code": "TANQUES-001", "categoryCode": "TANQUES", "sourceNumber": 1, "title": "ESTADO DEL TANQUE", "legalBasis": "Ley 13660 Decreto 10877 art 346", "glossary": "TANQUE A CIELO ABIERTO- CORROSION-INTEGRIDAD-PERDIADS DE HC- ESTADO ENVOLVENTE-PISO DAÑADO", "importNote": null }, { "code": "TANQUES-002", "categoryCode": "TANQUES", "sourceNumber": 2, "title": "BARANDAS-PLATAFORMAS-ESCALERAS-PISADERAS", "legalBasis": "Ley 13660 Decreto 10877 art 346 / Norma NAG 125 (Cap II - 2.3.)", "glossary": "PISADERA EN TECHO- BARANDA EN TECHO- ESCALERA EN TANQUE", "importNote": null }, { "code": "TANQUES-003", "categoryCode": "TANQUES", "sourceNumber": 3, "title": "INTEGRIDAD DEL TANQUE", "legalBasis": "API 650", "glossary": "PISO, TECHO, PAREDES (ESTADO GENERAL/ PÉRDIDAS)", "importNote": null }, { "code": "TANQUES-004", "categoryCode": "TANQUES", "sourceNumber": 4, "title": "VALVULAS TECHO DE TANQUE", "legalBasis": "Ley 13660 Decreto 10877, art 339, artt 340 - Decreto 1102/2024 art 33 - NFPA 30 art 21,4,3,10", "glossary": "PEFOW, VPV, CUELLO DE CISNE", "importNote": null }, { "code": "TANQUES-007", "categoryCode": "TANQUES", "sourceNumber": 7, "title": "CHAPA DE IDENTIFICACION", "legalBasis": "API 650", "glossary": null, "importNote": null }, { "code": "TANQUES-008", "categoryCode": "TANQUES", "sourceNumber": 8, "title": "CARTELERIA", "legalBasis": "Res 277/25", "glossary": null, "importNote": null }, { "code": "TANQUES-009", "categoryCode": "TANQUES", "sourceNumber": 9, "title": "SEÑALIZACION NFPA (ROMBO)", "legalBasis": "NFPA 704", "glossary": null, "importNote": null }, { "code": "TANQUES-010", "categoryCode": "TANQUES", "sourceNumber": 10, "title": "CAÑERIA (ESTADO /INDENTIFICACION)", "legalBasis": "NAG 123 // IRAM 2507 -NFPA 30 art 27.10", "glossary": null, "importNote": null }, { "code": "TANQUES-011", "categoryCode": "TANQUES", "sourceNumber": 11, "title": "PUESTA A TIERRA (CANTIDAD / MEDICION)", "legalBasis": "Ley 13660 Decreto 10877 art 336 - Decreto 1102/2024 art 33 inc II-A-e Ley 13.660, Decreto 10877/60, art. 336 (tanques)\nLey N° 19.587, Decreto N° 351/79, Anexo VI\nNorma NAG 125 (Cap II - 2.4.2.)", "glossary": null, "importNote": null }, { "code": "TANQUES-013", "categoryCode": "TANQUES", "sourceNumber": 13, "title": "BRIDAS (ESTADO / BULONERIA)", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "TANQUES-014", "categoryCode": "TANQUES", "sourceNumber": 14, "title": "DISTANCIAMIENTO MINIMO", "legalBasis": "Ley 13660 Decreto 10877, art 321", "glossary": null, "importNote": null }, { "code": "TANQUES-015", "categoryCode": "TANQUES", "sourceNumber": 15, "title": "RECINTO DE CONTENCION", "legalBasis": "Ley 13660 Decreto 10877, art 329, art 331 - NFPA 30 - NFPA 30 art 22// Res. SE 105/1992", "glossary": "(ESTADO / CAPACIDAD/ COTA DE LLENADO/ TAPAS Y/O PISADERAS)", "importNote": null }, { "code": "TANQUES-018", "categoryCode": "TANQUES", "sourceNumber": 18, "title": "CAMARA COLECTORA DE DRENAJE", "legalBasis": "Ley 13660 Decreto 10877 art 347", "glossary": null, "importNote": null }, { "code": "TANQUES-019", "categoryCode": "TANQUES", "sourceNumber": 19, "title": "CUMPLIMIENTO RESOLUCION 277/2025 TAAH", "legalBasis": "Res 277/25", "glossary": null, "importNote": null }, { "code": "TANQUES-020", "categoryCode": "TANQUES", "sourceNumber": 20, "title": "CARTELERIA DE SEGURIDAD", "legalBasis": "Ley 19587 art 9", "glossary": null, "importNote": null }, { "code": "TANQUES-024", "categoryCode": "TANQUES", "sourceNumber": 24, "title": "ORDEN Y LIMPIEZA", "legalBasis": "Ley 13.660, Decreto 10877/60, art. 230 y art. 354", "glossary": null, "importNote": null }, { "code": "SEPARADORES-001", "categoryCode": "SEPARADORES", "sourceNumber": 1, "title": "ESTADO GENERAL", "legalBasis": "Ley N° 19.587, decreto reglamentario N° 351/79", "glossary": null, "importNote": null }, { "code": "SEPARADORES-002", "categoryCode": "SEPARADORES", "sourceNumber": 2, "title": "CARTELERIA DE SEGURIDAD", "legalBasis": "Ley 19587 art 9", "glossary": null, "importNote": null }, { "code": "SEPARADORES-003", "categoryCode": "SEPARADORES", "sourceNumber": 3, "title": "PUESTA TIERRA", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "SEPARADORES-004", "categoryCode": "SEPARADORES", "sourceNumber": 4, "title": "RECINTO DE CONTENCIÓN", "legalBasis": "cv", "glossary": null, "importNote": null }, { "code": "SEPARADORES-005", "categoryCode": "SEPARADORES", "sourceNumber": 5, "title": "PLACA DE ESTALLIDO", "legalBasis": "Ley N° 19.587, decreto reglamentario N° 351/79, art.141", "glossary": null, "importNote": null }, { "code": "SEPARADORES-006", "categoryCode": "SEPARADORES", "sourceNumber": 6, "title": "VÁLVULA DE SEGURIDAD", "legalBasis": "Ley N° 19.587, decreto reglamentario N° 351/79, art.141\nNormas: NAG 125 (Cap. II - 2.11)// NAG 201", "glossary": null, "importNote": null }, { "code": "SEPARADORES-007", "categoryCode": "SEPARADORES", "sourceNumber": 7, "title": "MANOMETROS", "legalBasis": "Ley N° 19.587, decreto reglamentario N° 351/79, art.141", "glossary": null, "importNote": null }, { "code": "SEPARADORES-008", "categoryCode": "SEPARADORES", "sourceNumber": 8, "title": "VALVULA DE PURGA DE FONDO", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "SEPARADORES-009", "categoryCode": "SEPARADORES", "sourceNumber": 9, "title": "ESCALERAS Y PASARELAS", "legalBasis": "Norma NAG 125 (Cap II - 2.3.)", "glossary": null, "importNote": null }, { "code": "SEPARADORES-010", "categoryCode": "SEPARADORES", "sourceNumber": 10, "title": "ORDEN Y LIMPIEZA", "legalBasis": "Ley 13.660, Decreto 10877/60, art. 230 y art. 354", "glossary": null, "importNote": null }, { "code": "BOMBAS-001", "categoryCode": "BOMBAS", "sourceNumber": 1, "title": "ESTADO GENERAL (PERDIDAS)", "legalBasis": "DATOS DEL EQUIPO NFPA 30", "glossary": null, "importNote": null }, { "code": "BOMBAS-002", "categoryCode": "BOMBAS", "sourceNumber": 2, "title": "RECINTO DE CONTENCIÓN - CANALETAS -CAMARAS DE DRENAJE", "legalBasis": "Ley 13660 Decreto 10877/60, art 347, art.410, art. 989", "glossary": null, "importNote": null }, { "code": "BOMBAS-003", "categoryCode": "BOMBAS", "sourceNumber": 3, "title": "PUESTA A TIERRA", "legalBasis": "Ley 19587, Art.149", "glossary": null, "importNote": "La celda de título contenía el número 4; se normalizó por contexto y normativa." }, { "code": "BOMBAS-004", "categoryCode": "BOMBAS", "sourceNumber": 4, "title": "CARTELERIA INDICATIVA", "legalBasis": "Ley 19587 art 9", "glossary": null, "importNote": null }, { "code": "BOMBAS-005", "categoryCode": "BOMBAS", "sourceNumber": 5, "title": "ORDEN Y LIMPIEZA", "legalBasis": "Ley 13.660, Decreto 10877/60, art. 230 y art. 354", "glossary": null, "importNote": null }, { "code": "BOMBAS-006", "categoryCode": "BOMBAS", "sourceNumber": 6, "title": "SISTEMAS DE PROTECCION", "legalBasis": null, "glossary": "VÁLVULA DE SEGURIDAD EN BOMBAS DE DESPLAZAMIENTO POSITIVO", "importNote": null }, { "code": "BOMBAS-008", "categoryCode": "BOMBAS", "sourceNumber": 8, "title": "GUARDACORREA", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "BOMBAS-009", "categoryCode": "BOMBAS", "sourceNumber": 9, "title": "SISTEMA DE PURGA DEL EQUIPO", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "BOMBAS-010", "categoryCode": "BOMBAS", "sourceNumber": 10, "title": "CONDICIONES APE", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "CALDERAS-001", "categoryCode": "CALDERAS", "sourceNumber": 1, "title": "HABILITACIÓN POR ORGANISMO OFICIAL (DOCUMENTACIÓN)", "legalBasis": "Decreto 5475/71 - Decreto 2136-01 - Res 1066-2006 STSS", "glossary": null, "importNote": null }, { "code": "CALDERAS-002", "categoryCode": "CALDERAS", "sourceNumber": 2, "title": "CARNET HABILITANTE DEL OPERADOR (DOCUMENTACIÓN)", "legalBasis": "Decreto 5475/71 - Decreto 2136-01 - Res 1066-2006 STSS", "glossary": null, "importNote": null }, { "code": "CALDERAS-003", "categoryCode": "CALDERAS", "sourceNumber": 3, "title": "PRUEBA HIDRÁULICA HABILITADA POR ORGANISMO OFICIAL", "legalBasis": "Decreto 5475/71 - Decreto 2136-01 - Res 1066-2006 STSS", "glossary": null, "importNote": null }, { "code": "CALDERAS-004", "categoryCode": "CALDERAS", "sourceNumber": 4, "title": "ALARMA SONORA", "legalBasis": "Decreto 5475/71 - Decreto 2136-01 - Res 1066-2006 STSS", "glossary": null, "importNote": null }, { "code": "CALDERAS-005", "categoryCode": "CALDERAS", "sourceNumber": 5, "title": "ALARMA VISUAL", "legalBasis": "Decreto 5475/71 - Decreto 2136-01 - Res 1066-2006 STSS", "glossary": null, "importNote": null }, { "code": "CALDERAS-006", "categoryCode": "CALDERAS", "sourceNumber": 6, "title": "SOPLADO DE VÁLVULA DE SEGURIDAD", "legalBasis": "Decreto 5475/71 - Decreto 2136-01 - Res 1066-2006 STSS", "glossary": null, "importNote": null }, { "code": "CALDERAS-007", "categoryCode": "CALDERAS", "sourceNumber": 7, "title": "CALIBRACIÓN DE VÁLVULA DE SEGURIDAD", "legalBasis": "Decreto 5475/71 - Decreto 2136-01 - Res 1066-2006 STSS", "glossary": null, "importNote": null }, { "code": "CALDERAS-008", "categoryCode": "CALDERAS", "sourceNumber": 8, "title": "CONTROL DE NIVEL DE AGUA", "legalBasis": "Decreto 5475/71 - Decreto 2136-01 - Res 1066-2006 STSS", "glossary": null, "importNote": null }, { "code": "CALDERAS-009", "categoryCode": "CALDERAS", "sourceNumber": 9, "title": "CONTROL DE PRESIÓN", "legalBasis": "Decreto 5475/71 - Decreto 2136-01 - Res 1066-2006 STSS", "glossary": null, "importNote": null }, { "code": "CALDERAS-010", "categoryCode": "CALDERAS", "sourceNumber": 10, "title": "DATOS NECESARIOS", "legalBasis": "Decreto 5475/71 - Decreto 2136-01 - Res 1066-2006 STSS", "glossary": "Tipo de combustible, Presión de trabajo,", "importNote": null }, { "code": "CALDERAS-011", "categoryCode": "CALDERAS", "sourceNumber": 11, "title": "PURGA DE SUPERFICIE", "legalBasis": "Decreto 5475/71 - Decreto 2136-01 - Res 1066-2006 STSS", "glossary": null, "importNote": null }, { "code": "CALDERAS-012", "categoryCode": "CALDERAS", "sourceNumber": 12, "title": "PURGA DE FONDO", "legalBasis": "Decreto 5475/71 - Decreto 2136-01 - Res 1066-2006 STSS", "glossary": null, "importNote": null }, { "code": "CALDERAS-013", "categoryCode": "CALDERAS", "sourceNumber": 13, "title": "ESTADO DEL CUADRO DE COMBUSTIBLE", "legalBasis": "Decreto 5475/71 - Decreto 2136-01 - Res 1066-2006 STSS", "glossary": null, "importNote": null }, { "code": "CALDERAS-014", "categoryCode": "CALDERAS", "sourceNumber": 14, "title": "ESTADO DEL CUADRO DE AGUA", "legalBasis": "Decreto 5475/71 - Decreto 2136-01 - Res 1066-2006 STSS", "glossary": null, "importNote": null }, { "code": "CALDERAS-015", "categoryCode": "CALDERAS", "sourceNumber": 15, "title": "SISTEMA SHUT DOWN", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "DRENAJE-001", "categoryCode": "DRENAJE", "sourceNumber": 1, "title": "MATERIAL DE CONSTRUCCIÓN DE LA PILETA", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "DRENAJE-002", "categoryCode": "DRENAJE", "sourceNumber": 2, "title": "SELLO HIDRÁULICO (ESTADO)", "legalBasis": "Resolución 341/93 SEN", "glossary": null, "importNote": null }, { "code": "DRENAJE-003", "categoryCode": "DRENAJE", "sourceNumber": 3, "title": "PILETAS API (PROTECCIÓN DE AVES, CERCO, SEÑALIZACIÓN, DERRAMES, IMPERMEABILIZACIÓN)", "legalBasis": "Resolución 341/93 SEN", "glossary": null, "importNote": null }, { "code": "DRENAJE-004", "categoryCode": "DRENAJE", "sourceNumber": 4, "title": "PILETAS DE EMERGENCIA (NIVEL, PROTECCIÓN DE AVES, CERCO, SEÑALIZACIÓN, DERRAMES, IMPERMEABILIZACIÓN)", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "DRENAJE-005", "categoryCode": "DRENAJE", "sourceNumber": 5, "title": "SISTEMA DE CONTROL DE INCENDIOS (EXISTENCIA, ESTADO GENERAL)", "legalBasis": "NFPA 30", "glossary": null, "importNote": null }, { "code": "DRENAJE-006", "categoryCode": "DRENAJE", "sourceNumber": 6, "title": "ESTADO DE CÁMARAS (TAPADAS, PISADERAS)", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "DRENAJE-007", "categoryCode": "DRENAJE", "sourceNumber": 7, "title": "ESTADO DE CANALETAS (TAPADAS, PISADERAS)", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "ANTORCHA-001", "categoryCode": "ANTORCHA", "sourceNumber": 1, "title": "Llama encendida", "legalBasis": "Resolución 143/98 Art. 3.4", "glossary": null, "importNote": null }, { "code": "ANTORCHA-002", "categoryCode": "ANTORCHA", "sourceNumber": 2, "title": "Construccion/Operacion/Mantenimiento/Piloto", "legalBasis": "API STD 537", "glossary": null, "importNote": null }, { "code": "ANTORCHA-003", "categoryCode": "ANTORCHA", "sourceNumber": 3, "title": "humo negro, hollín / minimizar las emisiones de gases nocivos", "legalBasis": "Resolución 143/98 Art. 3.4", "glossary": null, "importNote": null }, { "code": "ANTORCHA-004", "categoryCode": "ANTORCHA", "sourceNumber": 4, "title": "sistema de medición instalado", "legalBasis": "Resolución 143/98 Art. 6.1.1", "glossary": null, "importNote": null }, { "code": "ANTORCHA-005", "categoryCode": "ANTORCHA", "sourceNumber": 5, "title": "registro de medición", "legalBasis": "Resolución 143/98 Art. 6.1.2", "glossary": null, "importNote": null }, { "code": "COLECTORES-001", "categoryCode": "COLECTORES", "sourceNumber": 1, "title": "PERDIDA", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "SISTEMA_ELECTRICO_ILUMINACION-001", "categoryCode": "SISTEMA_ELECTRICO_ILUMINACION", "sourceNumber": 1, "title": "Escasa iluminación y/o falta de ilumunación de emergencia en zona con actividad nocturna", "legalBasis": "Ley 19587 HyST, Dec. 351/79, Cap 12, Anexo IV_Infoleg", "glossary": null, "importNote": null }, { "code": "SISTEMA_ELECTRICO_ILUMINACION-002", "categoryCode": "SISTEMA_ELECTRICO_ILUMINACION", "sourceNumber": 2, "title": "Iluminación deficiente, cantidad e medición intensidad lumen insuficientes.", "legalBasis": "Ley 19587 HyST, Dec. 351/79, Cap 12, Anexo IV_Infoleg", "glossary": null, "importNote": null }, { "code": "SISTEMA_ELECTRICO_ILUMINACION-003", "categoryCode": "SISTEMA_ELECTRICO_ILUMINACION", "sourceNumber": 3, "title": "Dustribución de luminarias, layout del sistema.", "legalBasis": "Ley 19587 HyST, Dec. 351/79, Cap 12, Anexo IV_Infoleg", "glossary": null, "importNote": null }, { "code": "SISTEMA_ELECTRICO_ILUMINACION-004", "categoryCode": "SISTEMA_ELECTRICO_ILUMINACION", "sourceNumber": 4, "title": "Falta de puesta a tierra en columnas fijas", "legalBasis": "Ley 19587 HyST, Dec. 351/79, Cap 12, Anexo IV_Infoleg", "glossary": null, "importNote": null }, { "code": "SISTEMA_ELECTRICO_ILUMINACION-005", "categoryCode": "SISTEMA_ELECTRICO_ILUMINACION", "sourceNumber": 5, "title": "Palmeras o columnas de iluminación transportables, sistema de alimentación de energia.", "legalBasis": "Ley 19587 HyST, Dec. 351/79, Cap 12, Anexo IV_Infoleg", "glossary": null, "importNote": null }, { "code": "SISTEMA_ELECTRICO_ILUMINACION-006", "categoryCode": "SISTEMA_ELECTRICO_ILUMINACION", "sourceNumber": 6, "title": "Pararrayos dsitribución, cantidad, puesta a tierra de los mismos.", "legalBasis": "Ley 19587 HyST, Dec. 351/79, Cap 12, Anexo IV_Infoleg", "glossary": null, "importNote": null }, { "code": "DEFENSA_CONTRA_INCENDIOS-001", "categoryCode": "DEFENSA_CONTRA_INCENDIOS", "sourceNumber": 1, "title": "ESTADO GENERAL (PERDIDAS) de la motobombas", "legalBasis": "DATOS DEL EQUIPO NFPA 30", "glossary": null, "importNote": null }, { "code": "DEFENSA_CONTRA_INCENDIOS-002", "categoryCode": "DEFENSA_CONTRA_INCENDIOS", "sourceNumber": 2, "title": "RECINTO DE CONTENCIÓN - CANALETAS -CAMARAS DE DRENAJE", "legalBasis": "Ley 13660 Decreto 10877/60, art 347, art.410, art. 989 NFPA 30 art. 17.10.1", "glossary": null, "importNote": null }, { "code": "DEFENSA_CONTRA_INCENDIOS-003", "categoryCode": "DEFENSA_CONTRA_INCENDIOS", "sourceNumber": 3, "title": "PUESTA A TIERRA", "legalBasis": "Ley 19587, Art.149", "glossary": null, "importNote": null }, { "code": "DEFENSA_CONTRA_INCENDIOS-004", "categoryCode": "DEFENSA_CONTRA_INCENDIOS", "sourceNumber": 4, "title": "CARTELERIA INDICATIVA", "legalBasis": "Ley 19587 art 9", "glossary": null, "importNote": null }, { "code": "DEFENSA_CONTRA_INCENDIOS-005", "categoryCode": "DEFENSA_CONTRA_INCENDIOS", "sourceNumber": 5, "title": "ORDEN Y LIMPIEZA", "legalBasis": "Ley 13.660, Decreto 10877/60, art. 230 y art. 354", "glossary": null, "importNote": null }, { "code": "DEFENSA_CONTRA_INCENDIOS-006", "categoryCode": "DEFENSA_CONTRA_INCENDIOS", "sourceNumber": 6, "title": "SISTEMAS DE PROTECCION", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "DEFENSA_CONTRA_INCENDIOS-007", "categoryCode": "DEFENSA_CONTRA_INCENDIOS", "sourceNumber": 7, "title": "GUARDACORREA", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "DEFENSA_CONTRA_INCENDIOS-008", "categoryCode": "DEFENSA_CONTRA_INCENDIOS", "sourceNumber": 8, "title": "CONDICIONES APE", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "DEFENSA_CONTRA_INCENDIOS-009", "categoryCode": "DEFENSA_CONTRA_INCENDIOS", "sourceNumber": 9, "title": "existencia de la bombas de Jokey", "legalBasis": "NFPA 30", "glossary": null, "importNote": null }, { "code": "DEFENSA_CONTRA_INCENDIOS-010", "categoryCode": "DEFENSA_CONTRA_INCENDIOS", "sourceNumber": 10, "title": "estado en válvulas/juntas/lineas", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "DEFENSA_CONTRA_INCENDIOS-011", "categoryCode": "DEFENSA_CONTRA_INCENDIOS", "sourceNumber": 11, "title": "manómetro en pto más alejado y en salida de bomba", "legalBasis": "NFPA 30", "glossary": null, "importNote": null }, { "code": "DEFENSA_CONTRA_INCENDIOS-012", "categoryCode": "DEFENSA_CONTRA_INCENDIOS", "sourceNumber": 12, "title": "encendido manual", "legalBasis": "NFPA 30", "glossary": null, "importNote": null }, { "code": "DEFENSA_CONTRA_INCENDIOS-013", "categoryCode": "DEFENSA_CONTRA_INCENDIOS", "sourceNumber": 13, "title": "sistema de alimentación independiente de cada motobomba", "legalBasis": "NFPA 30", "glossary": null, "importNote": null }, { "code": "CARGADERO_DESCARGADERO-001", "categoryCode": "CARGADERO_DESCARGADERO", "sourceNumber": 1, "title": "Estado de accesos", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "CARGADERO_DESCARGADERO-002", "categoryCode": "CARGADERO_DESCARGADERO", "sourceNumber": 2, "title": "Indicador dirección de viento (Manga)", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "CARGADERO_DESCARGADERO-003", "categoryCode": "CARGADERO_DESCARGADERO", "sourceNumber": 3, "title": "Piso del cargadero (Grava - Cemento - Otro)", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "CARGADERO_DESCARGADERO-004", "categoryCode": "CARGADERO_DESCARGADERO", "sourceNumber": 4, "title": "Cámaras de drenaje", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "CARGADERO_DESCARGADERO-005", "categoryCode": "CARGADERO_DESCARGADERO", "sourceNumber": 5, "title": "Puesta a tierra (conexión eléctrica)", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "CARGADERO_DESCARGADERO-006", "categoryCode": "CARGADERO_DESCARGADERO", "sourceNumber": 6, "title": "Matafuegos (Cantidad - Tipo)", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "CARGADERO_DESCARGADERO-007", "categoryCode": "CARGADERO_DESCARGADERO", "sourceNumber": 7, "title": "Iluminación", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "CARGADERO_DESCARGADERO-008", "categoryCode": "CARGADERO_DESCARGADERO", "sourceNumber": 8, "title": "Orden y limpieza", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "CARGADERO_DESCARGADERO-009", "categoryCode": "CARGADERO_DESCARGADERO", "sourceNumber": 9, "title": "Línea de vida", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "FILTROS-001", "categoryCode": "FILTROS", "sourceNumber": 1, "title": "Perdiras de liquidos, uniones bridadas, soldadas, válvulas, piting.", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "FILTROS-002", "categoryCode": "FILTROS", "sourceNumber": 2, "title": "Identificación", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "FILTROS-003", "categoryCode": "FILTROS", "sourceNumber": 3, "title": "Puesta a tierra (conexión eléctrica)", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "EQUIPO_FLOTACION-001", "categoryCode": "EQUIPO_FLOTACION", "sourceNumber": 1, "title": "Perdiras de liquidos, uniones bridadas, soldadas, válvulas, piting.", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "EQUIPO_FLOTACION-002", "categoryCode": "EQUIPO_FLOTACION", "sourceNumber": 2, "title": "Identificación", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "EQUIPO_FLOTACION-003", "categoryCode": "EQUIPO_FLOTACION", "sourceNumber": 3, "title": "Puesta a tierra (conexión eléctrica)", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "BATERIAS_PLANTAS-001", "categoryCode": "BATERIAS_PLANTAS", "sourceNumber": 1, "title": "ADJUNTA P&ID", "legalBasis": "Decreto 351/79 (Anexo I)", "glossary": null, "importNote": null }, { "code": "BATERIAS_PLANTAS-002", "categoryCode": "BATERIAS_PLANTAS", "sourceNumber": 2, "title": "RED CONTRA INCENDIO / EXTINTORES", "legalBasis": "NFPA 30", "glossary": null, "importNote": null }, { "code": "BATERIAS_PLANTAS-003", "categoryCode": "BATERIAS_PLANTAS", "sourceNumber": 3, "title": "Caudalimetros de producción general, y gas (Existencia y Estado)", "legalBasis": "Ley N° 17.319 (Ley de Hidrocarburos): su Art. 75", "glossary": null, "importNote": null }, { "code": "BATERIAS_PLANTAS-004", "categoryCode": "BATERIAS_PLANTAS", "sourceNumber": 4, "title": "Piping y lineas de conducción, colores, nomenclaturas, sistema cosntructivo.", "legalBasis": "NAG 123", "glossary": null, "importNote": null }, { "code": "FWKO_TRATADORES_CALENTADORES-001", "categoryCode": "FWKO_TRATADORES_CALENTADORES", "sourceNumber": 1, "title": "Pretil", "legalBasis": "El Artículo 409 del Decreto Reglamentario 10.877 de la Ley 13.660", "glossary": null, "importNote": null }, { "code": "FWKO_TRATADORES_CALENTADORES-002", "categoryCode": "FWKO_TRATADORES_CALENTADORES", "sourceNumber": 2, "title": "válvula seguridad", "legalBasis": "Ley N° 19.587, decreto reglamentario N° 351/79, art.141", "glossary": null, "importNote": null }, { "code": "FWKO_TRATADORES_CALENTADORES-003", "categoryCode": "FWKO_TRATADORES_CALENTADORES", "sourceNumber": 3, "title": "Placa de estallido", "legalBasis": "Ley N° 19.587, decreto reglamentario N° 351/79, art.141", "glossary": null, "importNote": null }, { "code": "FWKO_TRATADORES_CALENTADORES-004", "categoryCode": "FWKO_TRATADORES_CALENTADORES", "sourceNumber": 4, "title": "Boca de Hombre", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "FWKO_TRATADORES_CALENTADORES-005", "categoryCode": "FWKO_TRATADORES_CALENTADORES", "sourceNumber": 5, "title": "Captación de gas", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "FWKO_TRATADORES_CALENTADORES-006", "categoryCode": "FWKO_TRATADORES_CALENTADORES", "sourceNumber": 6, "title": "Puesta a Tierra", "legalBasis": "Ley 13.660, Decreto 10877/60, art. 336 (tanques)\nLey N° 19.587, Decreto N° 351/79, Anexo VI\nNorma NAG 125 (Cap II - 2.4.2.)", "glossary": null, "importNote": null }, { "code": "FWKO_TRATADORES_CALENTADORES-007", "categoryCode": "FWKO_TRATADORES_CALENTADORES", "sourceNumber": 7, "title": "Cartelería", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "FWKO_TRATADORES_CALENTADORES-008", "categoryCode": "FWKO_TRATADORES_CALENTADORES", "sourceNumber": 8, "title": "Drenajes de fondo, estado y cantidad", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "FWKO_TRATADORES_CALENTADORES-009", "categoryCode": "FWKO_TRATADORES_CALENTADORES", "sourceNumber": 9, "title": "Instrumentos de Medición", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "FWKO_TRATADORES_CALENTADORES-010", "categoryCode": "FWKO_TRATADORES_CALENTADORES", "sourceNumber": 10, "title": "Instrumentos de control visusl estado", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "BOMBEO_MECANICO-001", "categoryCode": "BOMBEO_MECANICO", "sourceNumber": 1, "title": "Cartel Identificador de pozo en camino y en locacion", "legalBasis": "Res. SE 105/1992 — Art. 4 y 5, API RP 100-1 — Well Identification, IRAM 10005 — Señales de seguridad", "glossary": null, "importNote": null }, { "code": "BOMBEO_MECANICO-002", "categoryCode": "BOMBEO_MECANICO", "sourceNumber": 2, "title": "Cartelería Preventiva / Seguridad", "legalBasis": "Dec. 351/79 — Anexo IV (Ley 19.587), IRAM 10005 / ISO 7010, OSHA 1910.145 — Accident Prevention Signs", "glossary": null, "importNote": null }, { "code": "BOMBEO_MECANICO-003", "categoryCode": "BOMBEO_MECANICO", "sourceNumber": 3, "title": "Cerco perimetral AIB/ Puente de producción", "legalBasis": "Res. SE 105/1992 — Art. 7, Dec. 351/79 — Anexo I, Cap. XVIII, API RP 500 — Clasificación de Áreas,", "glossary": null, "importNote": null }, { "code": "BOMBEO_MECANICO-004", "categoryCode": "BOMBEO_MECANICO", "sourceNumber": 4, "title": "Cerco contrapesos", "legalBasis": "Res. SE 105/1992 — Art. 7 / Res. SRT 299/2011, Dec. 351/79 — Anexo I, Art. 114", "glossary": null, "importNote": null }, { "code": "BOMBEO_MECANICO-005", "categoryCode": "BOMBEO_MECANICO", "sourceNumber": 5, "title": "Guardacorreas / Escalera", "legalBasis": "Dec. 351/79 — Ley 19.587, Cap. XVIII, Res. SRT 299/2011 — Trabajos en Altura, ASME B20.1 — Safety Standard for Conveyors", "glossary": null, "importNote": null }, { "code": "BOMBEO_MECANICO-006", "categoryCode": "BOMBEO_MECANICO", "sourceNumber": 6, "title": "Protección y señalización de líneas de producción", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "BOMBEO_MECANICO-007", "categoryCode": "BOMBEO_MECANICO", "sourceNumber": 7, "title": "Puesta tierra: Motor AIB", "legalBasis": "Dec. 351/79 — Cap. XIII / Res. SRT 900/2015, AEA 90364 / IRAM 2281, IEC 60364-5-54 — Earthing Arrangements", "glossary": null, "importNote": null }, { "code": "BOMBEO_MECANICO-008", "categoryCode": "BOMBEO_MECANICO", "sourceNumber": 8, "title": "Puesta tierra: Tablero", "legalBasis": "AEA 90364 — Reglamento Electrotécnico AR, IRAM 2010 / IEC 60439 — Tableros BT", "glossary": null, "importNote": null }, { "code": "BOMBEO_MECANICO-009", "categoryCode": "BOMBEO_MECANICO", "sourceNumber": 9, "title": "Tablero y cableado (cable soterrado, riesgo electrico)", "legalBasis": "AEA 90364 — Instalaciones Eléctricas AR, Dec. 351/79 — Ley 19.587, Cap. XIII, API RP 500 / NFPA 70E — Electrical Safety, IEC 60079 — Atmósferas Explosivas (ATEX)", "glossary": null, "importNote": null }, { "code": "BOMBEO_MECANICO-010", "categoryCode": "BOMBEO_MECANICO", "sourceNumber": 10, "title": "Antepozo (Bodega)", "legalBasis": "Res. SE 105/1992 — Art. 9 y 10, Res. SRT 299/2011 — Espacios Confinados", "glossary": null, "importNote": null }, { "code": "BOMBEO_MECANICO-011", "categoryCode": "BOMBEO_MECANICO", "sourceNumber": 11, "title": "Puente producción (Estado)", "legalBasis": "Res. SE 105/1992 — Art. 11, API RP 14C — Surface Safety Systems", "glossary": null, "importNote": null }, { "code": "BOMBEO_MECANICO-012", "categoryCode": "BOMBEO_MECANICO", "sourceNumber": 12, "title": "Valvulas y línea Directa estado, empaquetadura estado", "legalBasis": "Res. SE 105/1992 — Art. 12, API 6A — Wellhead and Christmas Tree - API 6A — Wellhead Equipment, Normas operativas del operador", "glossary": null, "importNote": null }, { "code": "BOMBEO_MECANICO-013", "categoryCode": "BOMBEO_MECANICO", "sourceNumber": 13, "title": "Valvula EC Cerrada y tapon Ciego", "legalBasis": "Res. SE 105/1992 — Art. 12, API 6A / NACE MR0175", "glossary": null, "importNote": null }, { "code": "BOMBEO_MECANICO-014", "categoryCode": "BOMBEO_MECANICO", "sourceNumber": 14, "title": "Anclajes equipos de torre / Verificación-Protección", "legalBasis": "Res. SE 105/1992 — Art. 14 / CIRSOC 101, API Spec 11E — Pumping Units (Anclaje) CIRSOC 101 — Cargas Mínimas / INPRES-CIRSOC 103, Normas internas del operador — Integridad Mecánica", "glossary": null, "importNote": null }, { "code": "BOMBEO_MECANICO-015", "categoryCode": "BOMBEO_MECANICO", "sourceNumber": 15, "title": "Locación libre de derrames", "legalBasis": "Ley 25.675 — Ley General del Ambiente, Res. SE 25/2004 — Gestión Ambiental UP, Ley 17.319 — Art. 33 / Leyes provinciales", "glossary": null, "importNote": null }, { "code": "BOMBEO_MECANICO-016", "categoryCode": "BOMBEO_MECANICO", "sourceNumber": 16, "title": "Locación protegida por talud", "legalBasis": "Res. SE 25/2004 — Anexo I, punto 3.2, Normas provinciales (Neuquén Dec. 2453/2012)", "glossary": null, "importNote": null }, { "code": "BOMBEO_MECANICO-017", "categoryCode": "BOMBEO_MECANICO", "sourceNumber": 17, "title": "Vías de acceso/Escape/Emergencia", "legalBasis": "Dec. 351/79 — Ley 19.587, Cap. IX, Res. SRT 523/2007 — Planes de Emergencia, NFPA 101 — Life Safety Code", "glossary": null, "importNote": null }, { "code": "BOMBEO_MECANICO-018", "categoryCode": "BOMBEO_MECANICO", "sourceNumber": 18, "title": "Orden y limpieza general", "legalBasis": "Dec. 351/79 — Ley 19.587, Cap. IV Art. 42, ISO 45001 — Seguridad y Salud en el Trabajo", "glossary": null, "importNote": null }, { "code": "BOMBEO_ELECTROSUMERGIBLE-001", "categoryCode": "BOMBEO_ELECTROSUMERGIBLE", "sourceNumber": 1, "title": "Cartel Identificador de pozo en camino y en locacion", "legalBasis": "Res. SE 105/1992 — Art. 4 y 5, API RP 100-1 — Well Identification, IRAM 10005 — Señales de seguridad", "glossary": null, "importNote": null }, { "code": "BOMBEO_ELECTROSUMERGIBLE-002", "categoryCode": "BOMBEO_ELECTROSUMERGIBLE", "sourceNumber": 2, "title": "Cartelería Preventiva / Seguridad", "legalBasis": "Dec. 351/79 — Anexo IV (Ley 19.587), IRAM 10005 / ISO 7010, OSHA 1910.145 — Accident Prevention Signs", "glossary": null, "importNote": null }, { "code": "BOMBEO_ELECTROSUMERGIBLE-003", "categoryCode": "BOMBEO_ELECTROSUMERGIBLE", "sourceNumber": 3, "title": "Cerco perimetral BDP/ Puente de producción", "legalBasis": "Res. SE 105/1992 — Art. 7, Dec. 351/79 — Anexo I, Cap. XVIII, API RP 500 — Clasificación de Áreas,", "glossary": "Glosario", "importNote": null }, { "code": "BOMBEO_ELECTROSUMERGIBLE-004", "categoryCode": "BOMBEO_ELECTROSUMERGIBLE", "sourceNumber": 4, "title": "Puesta tierra: Motor, Gabinete de comando y Variador.", "legalBasis": "Dec. 351/79 — Cap. XIII / Res. SRT 900/2015, AEA 90364 / IRAM 2281, IEC 60364-5-54 — Earthing Arrangements", "glossary": null, "importNote": null }, { "code": "BOMBEO_ELECTROSUMERGIBLE-005", "categoryCode": "BOMBEO_ELECTROSUMERGIBLE", "sourceNumber": 5, "title": "Puesta tierra: Tablero", "legalBasis": "AEA 90364 — Reglamento Electrotécnico AR, IRAM 2010 / IEC 60439 — Tableros BT", "glossary": null, "importNote": null }, { "code": "BOMBEO_ELECTROSUMERGIBLE-006", "categoryCode": "BOMBEO_ELECTROSUMERGIBLE", "sourceNumber": 6, "title": "Tablero y cableado (cable soterrado, riesgo electrico)", "legalBasis": "AEA 90364 — Instalaciones Eléctricas AR, Dec. 351/79 — Ley 19.587, Cap. XIII, API RP 500 / NFPA 70E — Electrical Safety, IEC 60079 — Atmósferas Explosivas (ATEX)", "glossary": null, "importNote": null }, { "code": "BOMBEO_ELECTROSUMERGIBLE-007", "categoryCode": "BOMBEO_ELECTROSUMERGIBLE", "sourceNumber": 7, "title": "Antepozo (Bodega)", "legalBasis": "Res. SE 105/1992 — Art. 9 y 10, Res. SRT 299/2011 — Espacios Confinados", "glossary": null, "importNote": null }, { "code": "BOMBEO_ELECTROSUMERGIBLE-008", "categoryCode": "BOMBEO_ELECTROSUMERGIBLE", "sourceNumber": 8, "title": "Puente producción (Estado)", "legalBasis": "Res. SE 105/1992 — Art. 11, API RP 14C — Surface Safety Systems", "glossary": null, "importNote": null }, { "code": "BOMBEO_ELECTROSUMERGIBLE-009", "categoryCode": "BOMBEO_ELECTROSUMERGIBLE", "sourceNumber": 9, "title": "Valvulas y línea Directa estado, empaquetadura estado", "legalBasis": "Res. SE 105/1992 — Art. 12, API 6A — Wellhead and Christmas Tree - API 6A — Wellhead Equipment, Normas operativas del operador", "glossary": null, "importNote": null }, { "code": "BOMBEO_ELECTROSUMERGIBLE-010", "categoryCode": "BOMBEO_ELECTROSUMERGIBLE", "sourceNumber": 10, "title": "Valvula EC Cerrada y tapon Ciego", "legalBasis": "Res. SE 105/1992 — Art. 12, API 6A / NACE MR0175", "glossary": null, "importNote": null }, { "code": "BOMBEO_ELECTROSUMERGIBLE-011", "categoryCode": "BOMBEO_ELECTROSUMERGIBLE", "sourceNumber": 11, "title": "Anclajes equipos de torre / Verificación-Protección", "legalBasis": "Res. SE 105/1992 — Art. 14 / CIRSOC 101, API Spec 11E — Pumping Units (Anclaje) CIRSOC 101 — Cargas Mínimas / INPRES-CIRSOC 103, Normas internas del operador — Integridad Mecánica", "glossary": null, "importNote": null }, { "code": "BOMBEO_ELECTROSUMERGIBLE-012", "categoryCode": "BOMBEO_ELECTROSUMERGIBLE", "sourceNumber": 12, "title": "Locación libre de derrames", "legalBasis": "Ley 25.675 — Ley General del Ambiente, Res. SE 25/2004 — Gestión Ambiental UP, Ley 17.319 — Art. 33 / Leyes provinciales", "glossary": null, "importNote": null }, { "code": "BOMBEO_ELECTROSUMERGIBLE-013", "categoryCode": "BOMBEO_ELECTROSUMERGIBLE", "sourceNumber": 13, "title": "Locación protegida por talud", "legalBasis": "Res. SE 25/2004 — Anexo I, punto 3.2, Normas provinciales (Neuquén Dec. 2453/2012)", "glossary": null, "importNote": null }, { "code": "BOMBEO_ELECTROSUMERGIBLE-014", "categoryCode": "BOMBEO_ELECTROSUMERGIBLE", "sourceNumber": 14, "title": "Vías de acceso/Escape/Emergencia", "legalBasis": "Dec. 351/79 — Ley 19.587, Cap. IX, Res. SRT 523/2007 — Planes de Emergencia, NFPA 101 — Life Safety Code", "glossary": null, "importNote": null }, { "code": "BOMBEO_ELECTROSUMERGIBLE-015", "categoryCode": "BOMBEO_ELECTROSUMERGIBLE", "sourceNumber": 15, "title": "Orden y limpieza general", "legalBasis": "Dec. 351/79 — Ley 19.587, Cap. IV Art. 42, ISO 45001 — Seguridad y Salud en el Trabajo", "glossary": null, "importNote": null }, { "code": "BOMBEO_CAVIDAD_PROGRESIVA-001", "categoryCode": "BOMBEO_CAVIDAD_PROGRESIVA", "sourceNumber": 1, "title": "Cartel Identificador de pozo en camino y en locacion", "legalBasis": "Res. SE 105/1992 — Art. 4 y 5, API RP 100-1 — Well Identification, IRAM 10005 — Señales de seguridad", "glossary": null, "importNote": null }, { "code": "BOMBEO_CAVIDAD_PROGRESIVA-002", "categoryCode": "BOMBEO_CAVIDAD_PROGRESIVA", "sourceNumber": 2, "title": "Cartelería Preventiva / Seguridad", "legalBasis": "Dec. 351/79 — Anexo IV (Ley 19.587), IRAM 10005 / ISO 7010, OSHA 1910.145 — Accident Prevention Signs", "glossary": null, "importNote": null }, { "code": "BOMBEO_CAVIDAD_PROGRESIVA-003", "categoryCode": "BOMBEO_CAVIDAD_PROGRESIVA", "sourceNumber": 3, "title": "Cerco perimetral BDP/ Puente de producción", "legalBasis": "Res. SE 105/1992 — Art. 7, Dec. 351/79 — Anexo I, Cap. XVIII, API RP 500 — Clasificación de Áreas,", "glossary": null, "importNote": null }, { "code": "BOMBEO_CAVIDAD_PROGRESIVA-004", "categoryCode": "BOMBEO_CAVIDAD_PROGRESIVA", "sourceNumber": 4, "title": "Puesta tierra: Motor, Gabinete de comando y Variador.", "legalBasis": "Dec. 351/79 — Cap. XIII / Res. SRT 900/2015, AEA 90364 / IRAM 2281, IEC 60364-5-54 — Earthing Arrangements", "glossary": null, "importNote": null }, { "code": "BOMBEO_CAVIDAD_PROGRESIVA-005", "categoryCode": "BOMBEO_CAVIDAD_PROGRESIVA", "sourceNumber": 5, "title": "Puesta tierra: Tablero", "legalBasis": "AEA 90364 — Reglamento Electrotécnico AR, IRAM 2010 / IEC 60439 — Tableros BT", "glossary": null, "importNote": null }, { "code": "BOMBEO_CAVIDAD_PROGRESIVA-006", "categoryCode": "BOMBEO_CAVIDAD_PROGRESIVA", "sourceNumber": 6, "title": "Tablero y cableado (cable soterrado, riesgo electrico)", "legalBasis": "AEA 90364 — Instalaciones Eléctricas AR, Dec. 351/79 — Ley 19.587, Cap. XIII, API RP 500 / NFPA 70E — Electrical Safety, IEC 60079 — Atmósferas Explosivas (ATEX)", "glossary": null, "importNote": null }, { "code": "BOMBEO_CAVIDAD_PROGRESIVA-007", "categoryCode": "BOMBEO_CAVIDAD_PROGRESIVA", "sourceNumber": 7, "title": "Antepozo (Bodega)", "legalBasis": "Res. SE 105/1992 — Art. 9 y 10, Res. SRT 299/2011 — Espacios Confinados", "glossary": null, "importNote": null }, { "code": "BOMBEO_CAVIDAD_PROGRESIVA-008", "categoryCode": "BOMBEO_CAVIDAD_PROGRESIVA", "sourceNumber": 8, "title": "Puente producción (Estado)", "legalBasis": "Res. SE 105/1992 — Art. 11, API RP 14C — Surface Safety Systems", "glossary": null, "importNote": null }, { "code": "BOMBEO_CAVIDAD_PROGRESIVA-009", "categoryCode": "BOMBEO_CAVIDAD_PROGRESIVA", "sourceNumber": 9, "title": "Valvulas y línea Directa estado, empaquetadura estado", "legalBasis": "Res. SE 105/1992 — Art. 12, API 6A — Wellhead and Christmas Tree - API 6A — Wellhead Equipment, Normas operativas del operador", "glossary": null, "importNote": null }, { "code": "BOMBEO_CAVIDAD_PROGRESIVA-010", "categoryCode": "BOMBEO_CAVIDAD_PROGRESIVA", "sourceNumber": 10, "title": "Valvula EC Cerrada y tapon Ciego", "legalBasis": "Res. SE 105/1992 — Art. 12, API 6A / NACE MR0175", "glossary": null, "importNote": null }, { "code": "BOMBEO_CAVIDAD_PROGRESIVA-011", "categoryCode": "BOMBEO_CAVIDAD_PROGRESIVA", "sourceNumber": 11, "title": "Anclajes equipos de torre / Verificación-Protección", "legalBasis": "Res. SE 105/1992 — Art. 14 / CIRSOC 101, API Spec 11E — Pumping Units (Anclaje) CIRSOC 101 — Cargas Mínimas / INPRES-CIRSOC 103, Normas internas del operador — Integridad Mecánica", "glossary": null, "importNote": null }, { "code": "BOMBEO_CAVIDAD_PROGRESIVA-012", "categoryCode": "BOMBEO_CAVIDAD_PROGRESIVA", "sourceNumber": 12, "title": "Locación libre de derrames", "legalBasis": "Ley 25.675 — Ley General del Ambiente, Res. SE 25/2004 — Gestión Ambiental UP, Ley 17.319 — Art. 33 / Leyes provinciales", "glossary": null, "importNote": null }, { "code": "BOMBEO_CAVIDAD_PROGRESIVA-013", "categoryCode": "BOMBEO_CAVIDAD_PROGRESIVA", "sourceNumber": 13, "title": "Locación protegida por talud", "legalBasis": "Res. SE 25/2004 — Anexo I, punto 3.2, Normas provinciales (Neuquén Dec. 2453/2012)", "glossary": null, "importNote": null }, { "code": "BOMBEO_CAVIDAD_PROGRESIVA-014", "categoryCode": "BOMBEO_CAVIDAD_PROGRESIVA", "sourceNumber": 14, "title": "Vías de acceso/Escape/Emergencia", "legalBasis": "Dec. 351/79 — Ley 19.587, Cap. IX, Res. SRT 523/2007 — Planes de Emergencia, NFPA 101 — Life Safety Code", "glossary": null, "importNote": null }, { "code": "BOMBEO_CAVIDAD_PROGRESIVA-015", "categoryCode": "BOMBEO_CAVIDAD_PROGRESIVA", "sourceNumber": 15, "title": "Orden y limpieza general", "legalBasis": "Dec. 351/79 — Ley 19.587, Cap. IV Art. 42, ISO 45001 — Seguridad y Salud en el Trabajo", "glossary": null, "importNote": null }, { "code": "POZOS_SURGENTES_GAS-001", "categoryCode": "POZOS_SURGENTES_GAS", "sourceNumber": 1, "title": "Cartel Identificador de pozo en camino y en locacion", "legalBasis": "Res. SE 105/1992 — Art. 4 y 5, API RP 100-1 — Well Identification, IRAM 10005 — Señales de seguridad", "glossary": null, "importNote": null }, { "code": "POZOS_SURGENTES_GAS-002", "categoryCode": "POZOS_SURGENTES_GAS", "sourceNumber": 2, "title": "Cartelería Preventiva / Seguridad", "legalBasis": "Dec. 351/79 — Anexo IV (Ley 19.587), IRAM 10005 / ISO 7010, OSHA 1910.145 — Accident Prevention Signs", "glossary": null, "importNote": null }, { "code": "POZOS_SURGENTES_GAS-003", "categoryCode": "POZOS_SURGENTES_GAS", "sourceNumber": 3, "title": "Cerco perimetral BDP/ Puente de producción", "legalBasis": "Res. SE 105/1992 — Art. 7, Dec. 351/79 — Anexo I, Cap. XVIII, API RP 500 — Clasificación de Áreas,", "glossary": null, "importNote": null }, { "code": "POZOS_SURGENTES_GAS-004", "categoryCode": "POZOS_SURGENTES_GAS", "sourceNumber": 4, "title": "Medición en locación (estado)", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "POZOS_SURGENTES_GAS-005", "categoryCode": "POZOS_SURGENTES_GAS", "sourceNumber": 5, "title": "Separación de gas liquido, (estado)", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "POZOS_SURGENTES_GAS-006", "categoryCode": "POZOS_SURGENTES_GAS", "sourceNumber": 6, "title": "Tanque elevado (estado)", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "POZOS_SURGENTES_GAS-007", "categoryCode": "POZOS_SURGENTES_GAS", "sourceNumber": 7, "title": "Cargadero de camiones (estado)", "legalBasis": null, "glossary": null, "importNote": null }, { "code": "POZOS_INYECTORES_AGUA-001", "categoryCode": "POZOS_INYECTORES_AGUA", "sourceNumber": 1, "title": "Cartel Identificador de pozo en camino y en locacion", "legalBasis": "Res. SE 105/1992 — Art. 4 y 5, API RP 100-1 — Well Identification, IRAM 10005 — Señales de seguridad", "glossary": null, "importNote": null }, { "code": "POZOS_INYECTORES_AGUA-002", "categoryCode": "POZOS_INYECTORES_AGUA", "sourceNumber": 2, "title": "Cartelería Preventiva / Seguridad", "legalBasis": "Dec. 351/79 — Anexo IV (Ley 19.587), IRAM 10005 / ISO 7010, OSHA 1910.145 — Accident Prevention Signs", "glossary": null, "importNote": null }, { "code": "POZOS_INYECTORES_AGUA-003", "categoryCode": "POZOS_INYECTORES_AGUA", "sourceNumber": 3, "title": "Cerco perimetral BDP/ Puente de producción", "legalBasis": "Res. SE 105/1992 — Art. 7, Dec. 351/79 — Anexo I, Cap. XVIII, API RP 500 — Clasificación de Áreas,", "glossary": null, "importNote": null }, { "code": "POZOS_INYECTORES_AGUA-004", "categoryCode": "POZOS_INYECTORES_AGUA", "sourceNumber": 4, "title": "Control de Manómetros en tramos A, B, C.", "legalBasis": "Res. 81/1918 DGI", "glossary": null, "importNote": null } ];